{"id":33016,"date":"2026-01-28T08:04:40","date_gmt":"2026-01-28T08:04:40","guid":{"rendered":"https:\/\/emhabv.com\/project\/levensduurverlenging-door-trillingsreductie-in-afvalwatergemaal\/"},"modified":"2026-02-02T11:23:20","modified_gmt":"2026-02-02T11:23:20","slug":"service-life-extension-through-vibration-reduction-in-wastewater-pumping-station","status":"publish","type":"project","link":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/","title":{"rendered":"Lifetime extension through reduced vibrations in a wastewater pumping station"},"content":{"rendered":"\r\n<p><strong>On behalf of Hidrostal, EMHA carried out work on city pump P2 of the Bergen op Zoom sewage pumping station, managed by the Brabantse Delta Water Authority. The project was initiated due to elevated vibration levels that threatened the reliability and lifespan of the pump installation. Through targeted measurements, analysis, and a custom solution, EMHA restored the installation to stable and fully operational condition.<\/strong><\/p>\r\n<p>&nbsp;<\/p>\r\n<h2><strong>Situation<\/strong><\/h2>\r\n<p>The Bergen op Zoom sewage pumping station plays an important role in transporting wastewater within the Brabantse Delta Water Authority\u2019s service area. The pumps in the station operate continuously and must function reliably under varying conditions.<\/p>\r\n<p>In city pump P2, elevated vibration levels were observed. This posed a risk to the operational reliability of the installation and could eventually lead to malfunctions, increased maintenance, and accelerated wear.<\/p>\r\n<p>The purpose of the requested vibration measurements was to:<\/p>\r\n<ul>\r\n<li>determine the cause of the elevated vibration levels;<\/li>\r\n<li>use the measured frequencies and amplitudes as input for a finite element analysis;<\/li>\r\n<li>technically substantiate and validate the proposed solution with pipe and motor supports.<\/li>\r\n<\/ul>\r\n<p>&nbsp;<\/p>\r\n<h2><strong>EMHA\u2019s Solution<\/strong><\/h2>\r\n<p>EMHA conducted extensive vibration analyses at different operating points of city pump P2. The measurement results were compared with the permissible vibration values specified by the manufacturer.<\/p>\r\n<p>Based on this analysis, EMHA determined that the elevated vibrations were not primarily caused by the pump set itself, but by insufficient support of the motor and piping.<\/p>\r\n<p>EMHA then:<\/p>\r\n<ul>\r\n<li>designed a custom solution for additional support from the motor to the wall;<\/li>\r\n<li>produced the required supports;<\/li>\r\n<li>installed the supports on-site within one day.<\/li>\r\n<\/ul>\r\n<p>After installation, vibration measurements were repeated to verify the effectiveness of the measure.<\/p>\r\n<p>&nbsp;<\/p>\r\n<h2><strong>Result<\/strong><\/h2>\r\n<p>After installing the additional supports, the vibration levels returned to normal and permissible values. As a result, the pump can once again operate fully and reliably in the process.<\/p>\r\n<p>With this solution, EMHA has contributed directly to:<\/p>\r\n<ul>\r\n<li>improving operational reliability;<\/li>\r\n<li>extending the lifespan of the pump installation;<\/li>\r\n<li>reducing unplanned downtime and maintenance.<\/li>\r\n<\/ul>\r\n<p>By first measuring and analysing carefully, the true cause of the vibrations could be accurately identified. In many cases, issues of this nature are not caused by the pump set itself, but by the conditions in which the pump must operate.<\/p>\r\n<p>This approach prevents unnecessary replacement of components and results in a sustainable, cost\u2011efficient solution.<\/p>\r\n<p>&nbsp;<\/p>\r\n<h2><strong>Contact Us<\/strong><\/h2>\r\n<p>Experiencing vibration issues or performance loss in your pump installation? With EMHA Asset Insight, we provide clarity and a sustainable solution.<\/p>\r\n<p>Contact us to discover what we can do for your project.<\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"393\" height=\"263\" data-id=\"32694\" class=\"wp-image-32694 img-fluid i\" src=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding5-2.png\" alt=\"\" srcset=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding5-2.png 393w, https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding5-2-300x201.png 300w\" sizes=\"auto, (max-width: 393px) 100vw, 393px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"322\" height=\"259\" data-id=\"32693\" class=\"wp-image-32693 img-fluid i\" src=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding4-1.png\" alt=\"\" srcset=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding4-1.png 322w, https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding4-1-300x241.png 300w\" sizes=\"auto, (max-width: 322px) 100vw, 322px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"342\" height=\"262\" data-id=\"32692\" class=\"wp-image-32692 img-fluid i\" src=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding3-1.png\" alt=\"\" srcset=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding3-1.png 342w, https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding3-1-300x230.png 300w\" sizes=\"auto, (max-width: 342px) 100vw, 342px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"245\" height=\"333\" data-id=\"32691\" class=\"wp-image-32691 img-fluid i\" src=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png\" alt=\"\" srcset=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png 245w, https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1-221x300.png 221w\" sizes=\"auto, (max-width: 245px) 100vw, 245px\" \/><\/figure>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"248\" height=\"334\" data-id=\"32690\" class=\"wp-image-32690 img-fluid i\" src=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding1.png\" alt=\"\" srcset=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding1.png 248w, https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding1-223x300.png 223w\" sizes=\"auto, (max-width: 248px) 100vw, 248px\" \/><\/figure>\r\n<\/figure>\r\n","protected":false},"excerpt":{"rendered":"<p>On behalf of Hidrostal, EMHA carried out work on city pump P2 of the Bergen op Zoom sewage pumping station, managed by the Brabantse Delta Water Authority. The project was initiated due to elevated vibration levels that threatened the reliability and lifespan of the pump installation. Through targeted measurements, analysis, and a custom solution, EMHA &hellip;<\/p>\n","protected":false},"featured_media":33018,"template":"","location":[674],"specialism":[],"class_list":["post-33016","project","type-project","status-publish","has-post-thumbnail","hentry","location-international"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.0 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA<\/title>\n<meta name=\"description\" content=\"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA\" \/>\n<meta property=\"og:description\" content=\"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/\" \/>\n<meta property=\"og:site_name\" content=\"EMHA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T11:23:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"245\" \/>\n\t<meta property=\"og:image:height\" content=\"333\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/\",\"url\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/\",\"name\":\"Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA\",\"isPartOf\":{\"@id\":\"https:\/\/emhabv.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png\",\"datePublished\":\"2026-01-28T08:04:40+00:00\",\"dateModified\":\"2026-02-02T11:23:20+00:00\",\"description\":\"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.\",\"breadcrumb\":{\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage\",\"url\":\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png\",\"contentUrl\":\"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png\",\"width\":245,\"height\":333},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/emhabv.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"projecten\",\"item\":\"https:\/\/emhabv.com\/project\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Lifetime extension through reduced vibrations in a wastewater pumping station\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/emhabv.com\/#website\",\"url\":\"https:\/\/emhabv.com\/\",\"name\":\"EMHA\",\"description\":\"Wij realiseren betrouwbare en duurzame prestatieverbeteringen\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/emhabv.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA","description":"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/","og_locale":"en_US","og_type":"article","og_title":"Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA","og_description":"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.","og_url":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/","og_site_name":"EMHA","article_modified_time":"2026-02-02T11:23:20+00:00","og_image":[{"width":245,"height":333,"url":"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/","url":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/","name":"Lifetime extension through reduced vibrations in a wastewater pumping station - EMHA","isPartOf":{"@id":"https:\/\/emhabv.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage"},"image":{"@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage"},"thumbnailUrl":"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png","datePublished":"2026-01-28T08:04:40+00:00","dateModified":"2026-02-02T11:23:20+00:00","description":"EMHA optimized city pump P2 at the RG Grave sewage pumping station with custom pipe supports. Result: reduced vibrations and increased reliability.","breadcrumb":{"@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#primaryimage","url":"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png","contentUrl":"https:\/\/emhabv.com\/app\/uploads\/2026\/01\/Afbeelding2-1.png","width":245,"height":333},{"@type":"BreadcrumbList","@id":"https:\/\/emhabv.com\/en\/project\/service-life-extension-through-vibration-reduction-in-wastewater-pumping-station\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/emhabv.com\/en\/"},{"@type":"ListItem","position":2,"name":"projecten","item":"https:\/\/emhabv.com\/project\/"},{"@type":"ListItem","position":3,"name":"Lifetime extension through reduced vibrations in a wastewater pumping station"}]},{"@type":"WebSite","@id":"https:\/\/emhabv.com\/#website","url":"https:\/\/emhabv.com\/","name":"EMHA","description":"Wij realiseren betrouwbare en duurzame prestatieverbeteringen","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/emhabv.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/project\/33016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/types\/project"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/media\/33018"}],"wp:attachment":[{"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/media?parent=33016"}],"wp:term":[{"taxonomy":"location","embeddable":true,"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/location?post=33016"},{"taxonomy":"specialism","embeddable":true,"href":"https:\/\/emhabv.com\/en\/wp-json\/wp\/v2\/specialism?post=33016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}